myson.jpg (16676 bytes)

Low Water Temperature

Possible Cause Solution
Gas pressure too low. Checking gas inlet pressure.
Diaphragm pinholed or tore. Replace the diaphragm assembly - Pt. No. PMG 10/12460. Also, perform next step at the same time.
Automatic gas valve push rod is sticking. Dismantle clean and regrease using silicon grease. Handle the push rod with care, do not bend.
Slow ignition screw incorrectly set. The slow ignition screw is positioned above the sensing tubes in the water diaphragm housing. Turning the screw clockwise delays the ignition, counter-clockwise advances the ignition.. never turn the screw fully clockwise. When correct the burner ignition should be smooth and quiet when a hot water faucet is open.
Freeze/Corrosion damage to thermostat bulb. Replace Thermostat Bellows - Pt. No. PMG 10-13486.Do not overtighten thermostat bellows to spacer collar.
Thermostat Assembly(Pt.No. PMG 10/14536) jammed. Dismantle, Clean and Lubricate with silicone grease.  Do Not Overtighten Thermostat Bellows screws, collapsing metal spacer.
Incorrect water pressure. Constant water pressure should be 33+ PSI
High water flow rate set too high. Reset the water throttle to 2 GPM.

More questions?? Call (386) 767-9887 for Support!!

E-mail Us