Pilot Will Not Light

Possible Cause Solution
Gas not turned on. Turn on the gas at the manual gas valve and/or the main gas line. (At tank on LP Gas systems)
Air in Gas line. Purge the air line by depressing and holding the center 'Pilot/Start' button, this may take 2-3 minutes.
Incorrect pilot lighting procedure. Follow the lighting instructions located on the inside of the bottom  cover.
Electrode lead not connected to
the rear of the spark igniter.
Re-connect the electrode lead.
Incorrect spark gap Adjust the spark gap. The gap between the electrode tip and the pilot hood should be 1/8".
Electrode lead grounded out. Check that the electrode lead is routed clear of all metal parts.
Pilot injector blocked. Clear injector by blowing through or replace with pilot tube assembly part No PMG 10-12872 (Nat gas) or Part No PMG 10-12873 (LP Gas)
Faulty Components Replace any faulty components found. Piezo Unit - Part No PMG 10-11935. Electrode assembly - Part No PMG 10-12259.
No gas to the appliance. Call in your gas supplier

More questions??  Call (386) 767-9887 for Support !!