Orbis
Specifications
orbis heater
MARK I

MARK II
orbis heater
MARK III
Max. Input (BTUs/hr.) 8,000 15,000 20,000
Max. Output (BTUs/hr.) 5,650 10,845 14,800
Min. Input (BTUs/hr.) 4,000 7,500 10,000
Heated Room Size 115 - 180 sq.ft. 170 - 340 sq.ft 320 - 470 sq.ft.
Manifold Pressure (NAT) 4,0" w.c. 4,0" w.c. 4,0" w.c.
Min. Gas Pressure (NAT) 5,0" w.c. 5,0" w.c. 5,0" w.c.
Max. Gas Pressure (NAT) 7,0" w.c. 7,0" w.c. 7,0" w.c.
Manifold Pressure (LP) 10,0" w.c. 10,0" w.c. 10,0" w.c.
Min. Gas Pressure (LP) 11,0" w.c. 11,0" w.c. 11,0" w.c.
Max. Gas Pressure (LP) 13,0" w.c. 13,0" w.c. 13,0" w.c.
Gas Inlet Connection 3/8" NPT 3/8" NPT 3/8" NPT
Min. Wall Thickness 4" 4" 4"
Max. Wall Thickness 12" 12" 12"
Vent Opening in Wall 9-1/4" 9-1/4" 9-1/4"
Unit Height 25" 25" 25"
Unit Width 12" 20" 28"
Unit Depth 8" 10" 10"
Floor Clearance 6" 6" 6"
Shipping Weight (2 boxes) 40 lbs. 54 lbs. 64 lbs.

Call us at Appliances Services and Parts for more information 386-767-9887.