Specifications |
MYSON CF / DV 325 |
|
|---|---|---|
| Technical | ||
| BTU Input | 100,000 BTU Max / 50,000 BTU Min | |
| Temperature Adjustment | Automatic (90°.F Rise, Max Temp 140 ° F | |
| Gas Type | Natural or Propane | |
| Min Nat Gas Pressure | 06"W.C. | |
| Min LP Gas Pressure | 10 " W.C. | |
| Recovery Time | 101 Gal/Hour @ 90.0 ° F Rise | |
| Minimum Flow To Activate | 0.75 GPM | |
| Water Connections | 3/4" Male NPT | |
| Gas Connections | 3/4" Female NPT | |
| Minimum Water Pressure | 30.0 PSI Optimum Operating Pressure 35-50 PSI | |
| Maximum Water Pressure | 150.0 PSI | |
| Flow Rates | ||
| 50° Temperature Rise | 3.00 GPM - 180.0 Gal/ Hour | |
| 70° Temperature Rise | 2.15 GPM - 129.0 Gal/Hour | |
| 90° Temperature Rise | 1.68 GPM - 101.0 Gal/Hour | |
| Vent Sizes & Direct Vent Options | ||
| CF-325 - NG/LP | 5.0" Standard Type "B" Vent-Vented "From the Top" | |
| DV-325-NG/LP | 12"x12" Wall Opening-Vented "Through-The Outside Wall" | |
| DVK48 Vented Kits (std w/ DV | 6" Min Wall Thickness - 12" Max Wall Thickness | |
| DVEXT (Optional for DV) | 6" Min Wall Thickness - 24" Max Wall Thickness | |
| DVPWP (Optional for DV) | Required when exterior wall is any material other than masonry | |
| Height x Width x Depth | ||
| CF-325 | 34 1/2 x 16 5/8 x 10 7/8 Shipping Weight: 53 lbs. | |
| DV-325 | 29 3/8 x 16 5/8 x 10 7/8 Shipping Weight: 60 lbs. | |
| Minimum Clearance | ||
| CF-325 | DV-325 | |
| Top | 13" | 2" |
| Back | 0" | 0" |
| Sides | 2" | 2" |
| Bottom | 6" | 6" |
| Myson and Thermar water heater parts as well as FREE technical assistance is available from Appliances Services and Parts Company. For more information 386-767-9887. | ||